Technical Guide
Troubleshooting
guide
Troubleshooting guide
Wash Basins / Table Top
Wash Basins / Table Top
1. OVERFLOW CHOCKED AND FOUL BED ODOR
PROBABLE REASONS
Waste Coupling Used May Be Full Threaded
CORRECTIVE ACTIONS
Waste Coupling Should Be Changed To Slot Cut Coupling
2. WATER DEPOSIT ON TAP PLATFORM AREA AND INSIDE BOWL AREA
PROBABLE REASONS
Basin Is Not Fixed In Level Or Bracket Is Not In Level
CORRECTIVE ACTIONS
Should Be Done By Proper Leveling
3. THERE IS NO TAP HOLE IN BASIN
PROBABLE REASONS
Tap Hole Could Be Semi Punched From Back Side
CORRECTIVE ACTIONS
Tap Hole Should Be Created By Plumber From Semipunched Area
EWC I PAN / ANGLO INDIAN
EWC I PAN / ANGLO INDIAN
1. WATER NOT COMING IN BOWL AREA WHILE FLUSHING
PROBABLE REASONS
Flush Bend Is Not Inserted Up To The End Of Inlet Hole
Closet / Pan May Be Not Leveled
CORRECTIVE ACTIONS
Insert The Flush Pipe Up To The End Of Inlet ( For Pan Closet: Check Whether Flush Pipe Is Not Covering Flush Hole Which Is In Both Side Of Inlet Wall
Should Be Done By Proper Leveling
ONE PIECE CLOSET
ONE PIECE CLOSET
1. WATER NOT COMING IN BOWL AREA WHILE FLUSHING
PROBABLE REASONS
Mechanism Inside Tank Could Not Working Properly
There Is No Water In Flush Tank
CORRECTIVE ACTIONS
Change The Centre Pump Of Mechanism
Increase The Ball Cock Height To The Max Level
2. WATER IS CONTINUOUSLY LEAKING INSIDE THE BOWL
PROBABLE REASONS
Mechanism Inside Tank Could Not Working Properly
CORRECTIVE ACTIONS
Change The Centre Pump Of Mechanism
3. WATER QUANTITY INSUFFICIENT FOR EFFECTIVE FLUSHING
PROBABLE REASONS
Ball Cock Height Adjusted At Lower Level
CORRECTIVE ACTIONS
Increase The Ball Cock Height To The Max Level
4. UNEVEN FLOW OF WATER FROM BOTH SIDE OF CLOSET
PROBABLE REASONS
Closet Is Not Leveled Properly
CORRECTIVE ACTIONS
Closet Should Be In Proper Level
WALLHUNG WATER CLOSET
WALLHUNG WATER CLOSET
1. WATER NOT COMING IN BOWL AREA WHILE FLUSHING
PROBABLE REASONS
Flush Valve May Not Working Properly / Concealed Cistern Is Not Working Properly
CORRECTIVE ACTIONS
Should Change Flush Valve / Concealed Cistern
2. WATER IS CONTINUOUSLY LEAKING INSIDE THE BOWL
PROBABLE REASONS
Closet Is Not Leveled Properly
CORRECTIVE ACTIONS
Closet Should Be In Proper Level
3. WATER QUANTITY INSUFFICIENT FOR EFFECTIVE FLUSHING
PROBABLE REASONS
Connection Between Closet Outlet And Drainage Pipe Is Not Proper
CORRECTIVE ACTIONS
Should Be Done By Proper Connection By Experienced Plumber
COUPLE CLOSET (2 PCS CLOSET)
COUPLE CLOSET (2 PCS CLOSET)
1. UNEVEN FLOW OF WATER FROM BOTH SIDE OF CLOSET BOWL
PROBABLE REASONS
Both Arm Of Diverter Pipe Not Inserted Equally In Both Side Of The Closet
CORRECTIVE ACTIONS
Both Arm Of Diverter Pipe Should Be Inserted Equally In Both Side Of The Closet.
2. WATER IS LEAKING BETWEEN THE CISTERN AND CLOSET
PROBABLE REASONS
Diverter Pipe Not Fixed Properly In The Outlet Of Cistern
Rubber Ring Containing Bolt Is Not Tightened Properly
CORRECTIVE ACTIONS
Diverter Pipe Should Be Fixed Properly In The Outlet Of Cistern
Rubber Ring Containing Bolt Should Be Tightened Properly
TECHNICAL SPECIFICATION
TECHNICAL SPECIFICATION
Technical Specification of vitreous sanitary ware as per IS 2556 (Part) 1994.
SR. | NAME OF TEST | AS PER IS 2556 (Part) 1994 | OUR VALUE |
---|---|---|---|
1 | Water Absorption | Average value should not exceed more than 0.5 | Max 0.30% show better vitrification |
2 | Crazing Test | No crazing up to 2 cycle up 5 hrs each cycle or 10 hours at pressure 0.34 to 0.37 Mps. | No problem up to 4 cycle and no crazing |
3 | Chemical Resistance | No loss of reflectivity of the glaze when compared with control sample | No loss of reflectivity of the glaze when compared with control sample |
4 | Modules of Repture | Not less than 60 Mpa. | Min. 65 Mpa. / Min 80 Mpa. |
5 | Resistance to Staining and Burning | No stain shall remain on either of test piece | No stain shall remain on either of test piece |
6 | Discoloration | None on all visible surface | None on all visible surface |
7 | Wavy Finish | None on all visible surface | None on all visible surface |