Technical Guide

troble shooting guide

basin Wash Basins / Table Top

PROBABLE REASONS CORRECTIVE ACTIONS
Waste Coupling Used May Be Full Threaded Waste Coupling Should Be Changed To Slot Cut Coupling
PROBABLE REASONS CORRECTIVE ACTIONS
Basin Is Not Fixed In Level Or Bracket Is Not In Level Should Be Done By Proper Leveling
PROBABLE REASONS CORRECTIVE ACTIONS
Tap Hole Could Be Semi Punched From Back Side Tap Hole Should Be Created By Plumber From Semipunched Area

basin Ewc I Pan / Anglo Indian

PROBABLE REASONS CORRECTIVE ACTIONS
Flush Bend Is Not Inserted Up To The End Of Inlet Hole Insert The Flush Pipe Up To The End Of Inlet ( For Pan Closet: Check Whether Flush Pipe Is Not Covering Flush Hole Which Is In Both Side Of Inlet Wall
Closet / Pan May Be Not Leveled Should Be Done By Proper Leveling

basin One Piece Closet

PROBABLE REASONS CORRECTIVE ACTIONS
Mechanism Inside Tank Could Not Working Properly Change The Centre Pump Of Mechanism
There Is No Water In Flush Tank Increase The Ball Cock Height To The Max Level
PROBABLE REASONS CORRECTIVE ACTIONS
Mechanism Inside Tank Could Not Working Properly Change The Centre Pump Of Mechanism
PROBABLE REASONS CORRECTIVE ACTIONS
Ball Cock Height Adjusted At Lower Level Increase The Ball Cock Height To The Max Level
PROBABLE REASONS CORRECTIVE ACTIONS
Closet Is Not Leveled Properly Closet Should Be In Proper Level

basin Wallhung Water Closet

PROBABLE REASONS CORRECTIVE ACTIONS
Flush Valve May Not Working Properly / Concealed Cistern Is Not Working Properly Should Change Flush Valve / Concealed Cistern
PROBABLE REASONS CORRECTIVE ACTIONS
Closet Is Not Leveled Properly Closet Should Be In Proper Level
PROBABLE REASONS CORRECTIVE ACTIONS
Connection Between Closet Outlet And Drainage Pipe Is Not Proper Should Be Done By Proper Connection By Experienced Plumber

basin Couple Closet (2 Pcs Closet)

PROBABLE REASONS CORRECTIVE ACTIONS
Both Arm Of Diverter Pipe Not Inserted Equally In Both Side Of The Closet Both Arm Of Diverter Pipe Should Be Inserted Equally In Both Side Of The Closet.
PROBABLE REASONS CORRECTIVE ACTIONS
Diverter Pipe Not Fixed Properly In The Outlet Of Cistern Diverter Pipe Should Be Fixed Properly In The Outlet Of Cistern
Rubber Ring Containing Bolt Is Not Tightened Properly Rubber Ring Containing Bolt Should Be Tightened Properly

Technical Specification

Technical Specification of vitreous sanitary ware as per IS 2556 (Part) 1994.

SR. NAME OF TEST AS PER IS 2556 (Part) 1994 OUR VALUE
1 Water Absorption Average value should not exceed more than 0.5% Max 0.30% show better vitrification
2 Crazing Test No crazing up to 2 cycle up 5 hrs each cycle or 10 hours at pressure 0.34 to 0.37 Mps. No problem up to 4 cycle and no crazing
3 Chemical Resistance No loss of reflectivity of the glaze when compared with control sample No loss of reflectivity of the glaze when compared with control sample
4 Modules of Repture Not less than 60 Mpa. Min. 65 Mpa. / Min 80 Mpa.
5 Resistance to Staining and Burning No stain shall remain on either of test piece No stain shall remain on either of test piece
6 Discoloration None on all visible surface None on all visible surface
7 Wavy Finish None on all visible surface None on all visible surface